Skips every other label

(Print quality is good but skips every other label).

∙The label is formatted too close to the top edge of the form. Leave white space equal to 8-dot rows at the top of the label, approximately .02" (.5mm).

∙The media is not calibrated, (see Chapter 4)

∙The media sensor or media sensor circuitry may be defective, call for service.

Unable to print in rotation 4

∙The characters are formatted outside the dimensions of the label. Check that the row/column values provide enough room for the height of the characters or bar code to be printed.

Prints light on the right side of the label

∙The media width adjustment thumbwheel is set for a narrower media width than the actual media being used, (see Chapter 5).

∙The printhead is not properly aligned, call for service.

∙The printhead is not locked down.

Printer fails to turn on

∙A fuse may be blown, call for service.

∙Faulty AC cord, replace

∙A bad power switch may exist on the printer, call for service.

∙A faulty AC wall outlet.

48

E-4203/E-4204/E-4304

Page 58
Image 58
Datamax E-4304 manual Skips every other label