Datamax MP NOVA4 DT user manual Cancelling Test Methods

Models: MP NOVA4 DT

1 60
Download 60 pages 11.95 Kb
Page 43
Image 43

8. Troubleshooting

Test Method 2

Note: This method is only for advanced troubleshooting by service technicians.

This shows all information sent to the printer in hex-code and the function is used to determine possible communication faults, since it is possible to see exactly what data the printer receives.

1.Switch off the printer.

2.Press the print button, but do not release it.

3.Switch on the printer without releasing the print button.

4.Release the print button when the printer starts printing.

The printer starts by printing information as in test method 1. It then stops and will continue printing once the data is sent to the printer. By checking the received data, you can determine whether character received agree with the Label point- commands and the transferred ASCII- characters.

Differences between the received signals and the transferred characters may be due to incorrect parameters (e.g. Baud rate) or the presence of electrical inference during the transfer. Check the communication cable, the length of the cable and whether or not the cable is close to power cables.

Cancelling Test Methods

To cancel the test methods, turn the printer off and wait 15 seconds before switching it on again.

Page 43
Image 43
Datamax MP NOVA4 DT user manual Cancelling Test Methods