one memory module (if the computer supports a single module), and then restart the computer.

 

 

 

If the computer starts normally, move the memory module to a different connector and restart

 

 

 

the computer. Continue until you have identified a faulty connector or reinstalled all modules

 

 

 

without error.

 

 

If the problem persists, see "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining

 

 

technical assistance.

 

 

 

 

System board failure.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical assistance.

 

 

 

 

 

Memory modules are

Be sure that there are no special memory module/memory connector placement requirements.

 

detected, but a memory

Verify that the memory modules that you are installing are compatible with the computer.

 

configuration or compatibility

 

 

 

error exists.

If the problem persists, see "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining

 

 

 

 

technical assistance.

 

 

 

 

USB port or a device

Disconnect the device from the USB connector. If the problem persists, see "Contacting Dell" in the Dell

 

connected to it has failed

Owner's Manual for instructions on obtaining technical assistance.

 

initialization.

 

 

 

 

 

 

 

Other failure.

Ensure that the cables are properly connected from the hard drive, CD drive, and DVD drive to

 

 

 

the system board.

 

 

If the problem persists, see "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining

 

 

technical assistance.

 

 

 

 

Computer has started and

No action is necessary.

 

turned over control to the

 

 

 

operating system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Beep Codes

If the monitor cannot display errors or problems, during POST the computer might emit a series of beeps, or beep code, that identifies the problem. The POST beep codes are listed below.

Beep

 

 

Codes

Possible Cause

Corrective Action

 

 

 

1

A memory refresh failure occurred.

Reseat the memory modules.

 

 

 

2

Memory parity cannot be reset.

Reseat the memory modules.

 

 

 

3

A failure occurred in the first 64 KB of memory.

Reseat the memory modules.

4

The system timer is not operational.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

 

assistance.

 

 

 

6

8042 Gate A20 cannot be toggled.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

 

assistance.

 

 

 

7

An exception interrupt error occurred.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

 

assistance.

 

 

 

8

A read/write error occurred in the display

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

memory.

assistance.

 

 

 

10

A CMOS shutdown register test error occurred.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

 

assistance.

 

 

 

11

An invalid BIOS is installed.

See "Contacting Dell" in the Dell Owner's Manual for instructions on obtaining technical

 

 

assistance.

 

 

 

System Messages

Page 3
Image 3
Dell 4500 System Messages, System board, Beep Codes Possible Cause Corrective Action, Reseat the memory modules