Using the System Setup Program | 115
Option
Description
Remote Access
(Enabled default)
Disabled - Serial Console Redirection Off.
Enabled - Enables Serial Console Redirection.
Serial Port Number
(COM2 as SOL default)
COM1- serial Console Redirection On, output to
COM1. See also token D7h.
COM2 as SOL-serial Console redirection On, output
to COM2.
Serial Port Address
(3F8h/2F8h default)
3F8h/2F8h - By default, set rear serial port address as
0x3F8 and internal serial port address as 0x2F8.
2F8h/3F8h - Set rear serial port address as 0x2F8 and
internal serial port address as 0x3F8.
Serial Port Mode
(115200 8, n, 1 default)
Console Redirection baud rate will be set to 115,200/
57,600/ 38,400/ 19,200/ 9,600 bits per second.
Flow Control
(None default)
Remote access flow controls by none/
hardware/software.
Redirection After BIOS
POST
(Always default)
Always - The BIOS console redirection, if enabled,
continues to operate after the OS boot hand-off.
Disabled - The BIOS console redirection, if enabled,
operates during the BIOS boot only and is disabled
prior to OS boot hand-off. See also tokens BFh, C0h,
D7h, 401Ah and 401Bh.
Terminal Type
(ANSI default)
The BIOS console redirection, if enabled, operates in
VT100/VT-UTF8/ANSI emulation model. See also
tokens BFh, C0h, and D7h.
VT-UTF8 Combo Key
Support
(Enabled default)
Enables or disables VT-UTF8 combination key support
for ANSI/VT100 terminals.