Figure 3-18. Diagnostics Dialog Box

NOTE: A SIP may appear to be offline while it is being upgraded.

Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to the left of each item as that test finishes. The following table details each of the tests.

Table 3-5. Diagnostic Test Details

Test

Description

 

 

Memory Tests

Reports on the condition of the main board RAM

Firmware CRCs

Validates the current firmware images stored in the

 

system’s FLASH

Comm Interfaces

Validates internal communication pathways

Switch Controller test

Verifies the switch matrix controller is accessible

 

and functional

On-line SIPs

Indicates the total number of currently connected and

 

powered SIPs

Offline SIPs

Indicates the number of SIPs that have been connected

 

successfully in the past and are apparently powered down

Suspect SIPs

Indicates the number of SIPs that have been detected,

 

but are either unavailable for connection or have dropped

 

packets during the ping tests

To run diagnostic tests:

1If the OSCAR interface is not open, press <Print Screen>. The Main dialog box appears.

2Click Commands - Run Diagnostics. A warning message appears indicating that all users will be disconnected.

Basic Operation

41

Page 41
Image 41
Dell Console Switch manual Diagnostics Dialog Box, Diagnostic Test Details Description