Error Code

Message Information

 

 

 

Details

The processor temperature increased beyond the operational range.

 

Action

Review the logs for fan failures. If no fan failures are detected, check

 

 

inlet temperature (if available) and reinstall processor heat sink. If the

 

 

problem persists, see Getting Help.

CPU0005

Message

CPU <number> configuration is unsupported.

 

 

Details

System is unable to boot or may run in a degraded state.

 

Action

Review the technical specifications for supported processor types.

CPU0010

Message

CPU <number> is throttled.

 

 

Details

The CPU is throttled due to thermal or power conditions.

 

Action

Review system logs for power or thermal exceptions.

CPU0023

Message

CPU <number> is absent.

 

 

Action

Verify processor installation. If present, re-seat the processor.

CPU0204

Message

CPU <number> <name> voltage is outside of range.

 

 

Details

Voltages outside the allowable range may damage electrical

 

 

components or may cause the system to shutdown.

 

Action

1.

Turn off the system and remove input power for one minute.

 

 

 

 

2.

Ensure the processor is seated correctly.

 

 

3.

Reapply input power and turn on the system.

 

 

4.

If the issue persists, see Getting Help.

CPU0700

Message

CPU <number> initialization error detected.

 

 

Details

System BIOS was unable to initialize the processor.

 

Action

1.

Turn off the system and remove input power for one minute.

 

 

 

 

2.

Ensure the processor is seated correctly.

 

 

3.

Reapply input power and turn on the system.

 

 

4.

If the issue persists, see Getting Help.

CPU0701

Message

CPU <number> protocol error detected.

 

 

Details

System event log and operating system logs may indicate that the

 

 

exception is external to the processor.

105

Page 105
Image 105
Dell DR4100 CPU0005 Message, CPU0010 Message, CPU0023 Message, CPU0204 Message, CPU0700 Message, CPU0701 Message