Expanded Operating Temperature

NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.

< 10% of annual operating hours

5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.

 

NOTE: Outside the standard operating temperature

 

(10 °C to 35 °C), the system can operate down to 5 °C

 

or up to 40 °C for a maximum of 10% of its annual

 

operating hours.

 

For temperatures between 35 °C and 40 °C, de-rate

 

maximum allowable dry bulb temperature by 1 °C per 175

 

m above 950 m (1 °F per 319 ft).

< 1% of annual operating hours

–5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.

 

NOTE: Outside the standard operating temperature

 

(10 °C to 35 °C), the system can operate down to –5

 

°C or up to 45 °C for a maximum of 1% of its annual

 

operating hours.

 

For temperatures between 40 °C and 45 °C, de-rate

 

maximum allowable dry bulb temperature by 1 °C per 125

 

m above 950 m (1 °F per 228 ft).

Expanded Operating Temperature Restrictions

• Do not perform a cold startup below 5 °C.

 

 

• The operating temperature specified is for a

 

maximum altitude of 3048 m (10,000 ft).

 

• 130 W (4 core) processor is not supported.

 

• Redundant power supplies are required.

 

• Non Dell qualified peripheral cards and/or

 

peripheral cards greater than 25 W are not

 

supported.

 

• Maximum 95 W processor supported on 3.5 inch

 

hard drive chassis.

 

• Maximum 115 W processor supported on 2.5 inch

 

hard drive chassis.

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

Temperature

 

Maximum Temperature Gradient (Operating and

20 °C/h (36 °F/h)

Storage)

 

Storage Temperature Limits

–40 °C to 65 °C (–40 °F to 149 °F)

Temperature (Continuous Operation)

 

Temperature Ranges (for altitude less than 950 m or

10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on

3117 ft)

the equipment.