Error Code

Message Information

 

 

Action

Check the system operating environment.

TMP0120

Message

The system inlet temperature is greater than the upper warning

 

 

 

threshold.

 

Details

Ambient air temperature is too warm or one or more fans may have

 

 

failed.

 

Action

Check the system operating environment and review event log for fan

 

 

failures.

TMP0121

Message

The system inlet temperature is greater than the upper critical

 

 

 

threshold.

 

Details

Ambient air temperature is too warm or one or more fans may have

 

 

failed.

 

Action

Check the system operating environment and review event log for fan

 

 

failures.

VLT0204

Message

The system board <name> voltage is outside of the allowable range.

 

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.

2. Re-configure the system to minimum configuration, inspect and reinstall system cables.

3. If the issue persists, see Getting Help.

Warning Messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).

NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application.

Diagnostic Messages

The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See “Using System Diagnostics” chapter for more information about system diagnostics.

116

Page 116
Image 116
Dell DR4100 owner manual Diagnostic Messages, Failed, Failures, TMP0121 Message, VLT0204 Message