Error Code

Message Information

 

PSU0033

Message

The temperature for power supply <number> is outside of the

 

 

 

allowable range.

 

Details

System performance may be degraded.

 

Action

Check the system operating environment, including airflow and inlet

 

 

temperature. Check system logs for temperature and thermal

 

 

component failures.

PSU0034

Message

An under voltage fault detected on power supply <number>.

 

 

Details

This failure may be the result of an electrical issue with cables or

 

 

subsystem components in the system.

 

Action

1. Remove and reinstall the power supply.

 

 

 

 

2. Check cables and subsystem components in the system for

 

 

damage.

 

 

3. If the issue persists, see Getting Help.

PSU0035

Message

An over voltage fault detected on power supply <number>.

 

 

Action

Check input power or reinstall the power supply. If the issue persists,

 

 

see Getting Help.

PSU0036

Message

An over current fault detected on power supply <number>.

 

 

Details

This failure may be the result of an electrical issue with cables or

 

 

subsystem components in the system.

 

Action

1. Remove and reinstall the power supply.

 

 

 

 

2. Check cables and subsystem components in the system for

 

 

damage.

 

 

3. If the issue persists, see Getting Help.

PSU0037

Message

Fan failure detected on power supply <number>.

 

 

Action

Check for fan blockage. If the problem persists, see Getting Help.

PSU0076

Message

A power supply wattage mismatch is detected; power supply

 

 

 

<number> is rated for <value> watts.

 

Details

Power supplies should be of the same input type and power rating.

 

Action

Install matched power supplies and review this manual for proper

 

 

configuration.

112

Page 112
Image 112
Dell DR4100 PSU0033 Message, PSU0034 Message, PSU0035 Message, PSU0036 Message, PSU0037 Message, PSU0076 Message