At the first detection of an EqualLogic array, an MTU of 12000 is enabled on all ports and port-
channels (if it has not already been enabled).
Spanning-tree portfast is enabled on the interface LLDP identifies.
Unicast storm control is disabled on the interface LLDP identifies.
Configuring Detection and Ports for Dell Compellent Arrays
For the best iSCSI traffic conditions, the MXL switch auto-configures a port connected to a Dell
Compellent storage array, when configured as compellent connected port through CLI.
The following message displays the first time a Dell Compellent storage array is detected and describes
the configuration changes that are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured
for optimal
conditions to support iSCSI traffic which will cause some automatic
configuration to occur
including jumbo frames and flow-control on all ports; no storm control and
spanning-tree port
fast to be enabled on the port of detection.
The MXL switch auto-configures as follows:
At the first detection, an MTU of 12000 is enabled on all ports and port-channels (if it is not already
enabled).
Spanning-tree portfast is enabled on the interface identified by CLI, if the port is in L2 mode.
Unicast storm control is disabled on the interface identified by CLI.
iSCSI Optimization: Operation
iSCSI optimization requires LLDP to be enabled. LLDP is enabled by default on MXL switch.
When the MXL auto-configures with iSCSI enabled, the following actions occurs:
Link-level flow control is enabled on PFC disabled interfaces.
iSCSI session snooping is enabled.
iSCSI LLDP monitoring starts to automatically detect EqualLogic arrays.
The following message displays when you enable iSCSI on a switch and describes the configuration
changes that are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_ENABLE: iSCSI has been enabled causing flow
control to be enabled on all interfaces. EQL detection and enabling iscsi
profile-compellent on an interface may cause some automatic configurations to
occur like jumbo frames on all ports and no storm control and spanning tree
port-fast on the port of detection.
478 iSCSI Optimization