Master Switch Fails
Problem: The master switch fails due to a hardware fault, software crash, or power loss.
Resolution: A failover procedure begins:
1. Keep-alive messages from the MXL 10/40GbE master switch time out after 60 seconds and the
switch is removed from the stack.
2. The standby switch takes the master role. Data traffic on the new master switch is uninterrupted.
Protocol traffic is managed by the control plane.
3. A member switch is elected as the new standby. Data traffic on the new standby is uninterrupted.
The control plane prepares for operation in Warm Standby mode.
Stack-Link Flapping Error
Problem/Resolution: Stacked MXL 10/40GbE Switches monitor their own stack ports and disable any
stack port that flaps five times within 10 seconds. If the stacking ports that flap are on the master or
standby, KERN-2-INT error messages note the units
To re-enable a downed stacking port, power cycle the stacked switch on which the port is installed.
The following is an example of the stack-link flapping error message.
--------------------------------------MANAGMENT
UNIT-----------------------------------------
Error: Stack Port 49 has flapped 5 times within 10 seconds.Shutting down this
stack port now.
Error: Please check the stack cable/module and power-cycle the stack.
10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times
within 10
seconds.Shutting down this stack port now.
10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/
module and
power-cycle the stack.
---------------------------------------STANDBY
UNIT------------------------------------------
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times
within 10
seonds.Shutting down this stack port now.
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
----------------------------------------MEMBER
2---------------------------------------------
Error: Stack Port 51 has flapped 5 times within 10 seconds.Shutting down this
stack port now.
Error: Please check the stack cable/module and power-cycle the stack.
Master Switch Recovers from Failure
Problem: The master switch recovers from a failure after a reboot and rejoins the stack:
As a member unit if there is already a standby
As a standby if there is no standby in the stack
The protocol and control plane recovery requires time before the switch is fully online.
Resolution: When the entire stack is reloaded, the recovered master switch becomes the master unit
of the stack.
Stacking 903