Dell(config)# interface tengigabitethernet 1/0
Dell(config-if-te-0/0)#dcb-map SAN_DCB_MAP
3. Create the dedicated VLAN to be used for FCoE traffic:
Dell(conf)#interface vlan 1002
4. Configure an FCoE map to be applied on downstream (server-facing) Ethernet and upstream (core-
facing) FC ports:
Dell(config)# fcoe-map SAN_FABRIC_A
Dell(config-fcoe-name)# fabric-id 1002 vlan 1002
Dell(config-fcoe-name)# description "SAN_FABRIC_A"
Dell(config-fcoe-name)# fc-map 0efc00
Dell(config-fcoe-name)# keepalive
Dell(config-fcoe-name)# fcf-priority 128
Dell(config-fcoe-name)# fka-adv-period 8
5. Enable an upstream FC port:
Dell(config)# interface fibrechannel 0/0
Dell(config-if-fc-0)# no shutdown
6. Enable a downstream Ethernet port:
Dell(config)#interface tengigabitEthernet 0/0
Dell(conf-if-te-0)# no shutdown
Displaying NPIV Proxy Gateway Information
To display information on the NPG operation, use the show commands in the following table
Table 84. Displaying NPIV Proxy Gateway Information
Command Description
show interfaces status Displays the operational status of Ethernet and Fibre Channel
interfaces on an MXL 10/40GbE Switch or M I/O Aggregator
with the FC Flex IO module, NPG.
1088 FC Flex IO Modules