FCoE devices are reachable. Default: FIP keep-
alive monitoring is enabled.
7Configure the time interval (in seconds) used
to transmit FIP keepalive advertisements.
Range: 8-90 seconds. Default: 8 seconds.
fka-adv-period
seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as fabric discovery
(FDISC) messages to a SAN switch.
Step Task Command Command Mode
1Configure a server-facing Ethernet port or
port channel with an FCoE map. interface
{tengigabitEthernet
slot/port |
fortygigabitEthernet
slot/port | port-
channel num}
CONFIGURATION
2Apply the FCoE/FC configuration in an FCoE
map on the Ethernet port. Repeat this step to
apply an FCoE map to more than one port, for
example:
Dell# interface tengigabitEthernet
0/0Dell(config-if-te-0/0)# fcoe-map
SAN_FABRIC_ADell# interface port-
channel 3Dell(config-if-po-3)#
fcoe-map SAN_FABRIC_ADell#
interface fortygigabitEthernet
0/48Dell(config-if-fo-0/0)# fcoe-
map SAN_FABRIC_A
fcoe-map map-name INTERFACE or
INTERFACE
PORT_CHANNEL
3Enable the port for FCoE transmission using
the map settings. no shutdown INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The MXL 10/40GbE Switch and M I/O Aggregator, with the FC Flex IO module FC ports, are configured by
default to operate in N port mode to connect to an F port on an FC switch in a fabric. You can apply only
one FCoE map on an FC port.
1086 FC Flex IO Modules