Error Code

Message Information

 

 

Action

Remove and reinstall the fan. If the issue persists, see Getting

 

 

Help.

HWC1001

Message

The <name> is absent.

 

 

Details

The absent device may be necessary for proper operation.

 

 

System functionality may be degraded.

 

Action

Reinstall or reconnect the hardware.

HWC2003

Message

The storage <name> cable is not connected, or is improperly

 

 

 

connected.

 

Details

The cable may be necessary for proper operation. System

 

 

functionality may be degraded.

 

Action

Check if the cable is present, then reinstall or reconnect.

HWC2005

Message

The system board <name> cable is not connected, or is

 

 

 

improperly connected.

 

Details

The cable may be necessary for proper operation. System

 

 

functionality may be degraded.

 

Action

Check if the cable is present, then reinstall or reconnect.

MEM0000

Message

Persistent correctable memory errors detected on a memory

 

 

 

device at location(s) <location>.

 

Details

This is an early indicator of a possible future uncorrectable

 

 

error.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help .

MEM0001

Message

Multi-bit memory errors detected on a memory device at

 

 

 

location(s) <location>.

 

Details

The memory module has encountered an uncorrectable

 

 

error. System performance may be degraded. The operating

 

 

system and/or applications may fail as a result.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

MEM0007

Message

Unsupported memory configuration; check memory device

 

at location <location>.

91