Menu Item

Description

SR-IOV Global Allows you to enable or disable the BIOS configuration of Single Root I/O

EnableVirtualization (SR-IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.

Memory Mapped Allows you to enable support for PCIe devices that require large amounts of

I/O above 4GB memory. By default, the option is set to Enabled.

Slot Disablement Allows you to enable or disable available PCIe slots on your system. The Slot Disablement feature controls the configuration of PCIe cards installed in the specified slot.

CAUTION: Slot disablement must be used only when the installed peripheral card is preventing booting into the Operating System or causing delays in system startup. If the slot is disabled, both the Option ROM and UEFI driver are disabled.

Serial Communications Screen

Menu Item

Description

Serial

Allows you to select serial communication devices (Serial Device 1 and Serial

Communication

Device 2) in the BIOS. BIOS console redirection can also be enabled and the port

 

address used can be specified. By default, Serial Communication option is set to

 

On without Console Redirection.

Serial Port Address

Allows you to set the port address for serial devices. By default, the Serial Port

 

Address option is set to Serial Device 1=COM2, Serial Device 2=COM1.

 

NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use

 

console redirection by SOL, configure the same port address for console

 

redirection and the serial device.

External Serial

Allows you to associate the external serial connector to serial device 1, serial device

Connector

2, or remote access device. By default, the External Serial Connector option is set

 

to Serial Device1.

 

NOTE: Only Serial Device 2 can be used for SOL. To use console redirection

 

by SOL, configure the same port address for console redirection and the serial

 

device.

Failsafe Baud Rate

Displays the failsafe baud rate for console redirection. The BIOS attempts to

 

determine the baud rate automatically. This failsafe baud rate is used only if the

 

attempt fails and the value must not be changed. By default, the Failsafe Baud Rate

 

option is set to 115200.

Remote Terminal

Allows you to set the remote console terminal type. By default, the Remote

Type

Terminal Type option is set to VT 100/VT 220.

Redirection After

Allows you to enable or disable to the BIOS console redirection when the

Boot

operating system is loaded. By default, the Redirection After Boot option is set to

 

Enabled.

19

Page 19
Image 19