Dell R220 owner manual BAT0002 Message

Models: R220

1 98
Download 98 pages 50.8 Kb
Page 88
Image 88

Error Code

Message Information

 

 

Details

The operating system or an application failed to

 

 

communicate within the time-out period. The system was

 

 

power-cycled.

 

Action

Check the operating system, application, hardware, and

 

 

system event log for exception events.

BAT0002

Message

The system board battery has failed.

 

 

Details

The system board battery is either missing or bad.

 

Action

See Getting Help.

BAT0017

Message

The <name> battery has failed.

 

 

Details

The <name> battery is either missing, bad, or unable to

 

 

charge due to thermal issues.

 

Action

Check system fans. If the problem persists, see Getting Help.

CPU0000

Message

CPU <number> has an internal error (IERR).

 

 

Details

System Event Log and Operating System Logs may indicate

 

 

that the exception is external to the processor.

 

Action

Review System Event Log and Operating System Logs. If the

 

 

issue persists, see Getting Help.

CPU0001

Message

CPU <number> has a thermal trip (over-temperature) event.

 

 

Details

The processor temperature increased beyond the

 

 

operational range.

 

Action

Review the logs for fan failures. If no fan failures are

 

 

detected, check inlet temperature (if available) and reinstall

 

 

processor heat sink. If the problem persists, see Getting Help.

CPU0005

Message

CPU <number> configuration is unsupported.

 

 

Details

System is unable to boot or may run in a degraded state.

 

Action

Review the technical specifications for supported processor

 

 

types.

CPU0010

Message

CPU <number> is throttled.

 

 

Details

The CPU is throttled due to thermal or power conditions.

 

Action

Review system logs for power or thermal exceptions.

88

Page 88
Image 88