Dell R710 E1000 Failsafe, Voltage, Error, Contact, Support, E1114 Ambient Temp, Exceeds, Allowed

Models: R710

1 208
Download 208 pages 35.88 Kb
Page 24
Image 24

Table 1-1. LCD Status Messages

Code

Text

Cause

Corrective Actions

 

 

 

 

E1000

Failsafe

Check the system event log

Remove AC power to the

 

voltage

for critical failure events.

system for 10 seconds and

 

error.

 

restart the system.

 

Contact

 

If the problem persists,

 

support.

 

 

 

see "Getting Help."

 

 

 

 

 

 

 

E1114

Ambient Temp

Ambient temperature has a

See "Troubleshooting

 

exceeds

reached a point outside of

System Cooling

 

allowed

the allowed range.

Problems."

 

range.

 

 

E1116 Memory

Memory has exceeded

disabled,

allowable temperature and

temp above

has been disabled to

range. Power

prevent damage to the

cycle AC.

components.

Remove AC power to the system for 10 seconds and restart the system.

See "Troubleshooting System Cooling Problems." If the problem persists, see "Getting Help."

E1210 Motherboard

CMOS battery is missing or

See "Troubleshooting the

battery

the voltage is outside of the

System Battery."

failure.

allowable range.

 

Check

 

 

battery.

 

 

E1211 RAID

RAID battery is either

Controller

missing, bad, or unable to

battery

recharge due to thermal

failure.

issues.

Check

 

battery.

 

Reseat the RAID battery connector. See "Installing a RAID Battery" and "Troubleshooting System Cooling Problems."

E1216 3.3V

3.3V voltage regulator has

Remove and reseat the

Regulator

failed.

PCIe expansion cards. If

failure.

 

the problem persists, see

Reseat PCIe

 

"Troubleshooting

cards.

 

Expansion Cards."

24

About Your System

Page 24
Image 24
Dell R710 E1000 Failsafe, Voltage, Error, Contact, Support, E1114 Ambient Temp, Exceeds, Allowed, Range E1116 Memory