Configuration Utility Error Messages

NOTE: These error messages are displayed inside the Configuration Utility. Restart your system and retry if you encounter any of these.

Table 6-3. Configuration Utility Error Messages

Message

Meaning and Suggested Solution

 

 

An error occurred while reading

An error reading any one of a number of settings from the

non-volatile settings.

firmware. Reseat the controller and reboot.

 

 

An error occurred while reading

Controller setup and initialization has failed. Reboot the

current controller settings.

system.

 

 

Advanced Device Properties settings

Failed to read vital configuration page from firmware. Reflash

not found.

the firmware and reboot.

 

 

Advanced Adapter Properties settings

Failed to read vital configuration page from firmware.Reflash

not found.

the firmware and reboot.

 

 

Error obtaining PHY properties

Failed to read vital configuration page from firmware.Reflash

configuration information.

the firmware and reboot.

 

 

Configuration Utility Options Image

Failed to properly read Configuration Utility options from

checksum error.

flash. Restart and retry. If the issue persists, reflash the

 

firmware on the controller.

 

 

Configuration Utility Options Image

Failed to properly read Configuration Utility options from

error.

flash. Restart and retry. If the issue persists, reflash the

 

firmware on the controller.

 

 

Configuration Utility Options Image

Failed to properly read Configuration Utility options from

not found.

flash. Restart and retry. If the issue persists, reflash the

 

firmware on the controller.

 

 

Can't load default Configuration

Failed to allocate memory for Configuration Utility options

Utility options.

structure.

 

 

An error occurred while writing

An error occurred while writing one or more settings to the

non-volatile settings.

firmware.

 

 