FUELS

4

FUELS VENTILATION THEORY OF OPERATION

FUELS

THEORY OF OPERATION

THEORY OF OPERATION WARNING: Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol or other highly flammable fuels.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in:

clogged fuel filter and nozzle

use of non-toxic anti-icer in fuel during very cold weather

IMPORTANT: Use a KEROSENE ONLY container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to shut down heater. Foreign matter may also require you to clean fuel system often.

VENTILATION

VENTILATION WARNING: Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ven- tilation before running heater.

Provide a fresh air opening of at least 2800 square cm (three square feet) for each 30kw (100,000 Btu/Hr) rating. Provide extra fresh air if more heaters are being used.

The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The ignition control assembly provides power to the ignitor. This ignites the fuel/air mixture in the combus- tion chamber.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.

Combustion

Ignitor

 

Motor

Air Pump

Chamber

 

Fan

Air Intake

 

 

 

 

 

 

Filter

 

 

 

 

 

Clean

 

 

 

 

 

Heated

 

 

 

 

Cool

Air Out

 

 

 

 

Air In

 

 

 

 

 

Air

 

 

 

 

 

Output

 

 

 

 

 

Filter

Fuel

 

 

 

Air Line

Ignition

Nozzle

Fuel

Control

Tank

Filter

To Burner

Assembly

 

 

 

Air For Fuel

Air For

 

Fuel

 

Combustion

 

System

 

 

And Heating

Figure 4 - Cross Section Operational View