Desa GK30, GK20 Operation, Storing, Transporting, Or Shipping, To Start Heater, To Stop Heater

Models: GK30 GK20

1 94
Download 94 pages 58.39 Kb
Page 7
Image 7
OPERATION

OPERATION STORING, TRANSPORTING, OR SHIPPING

5

OPERATION

TO START HEATER WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Plug power cord of heater into standard 240 volt/50 hertz, grounded (earthed) outlet. Use an extension cord if needed. Use only a three-prong, grounded (earthed) extension cord.

EXTENSION CORD WIRE SIZE

REQUIREMENTS

Up to 30.5 meters (100 feet) long, use 1.0 mm2 (16 AWG) conductor

30.6to 61 meters (101 to 200 feet) long, use 1.5 mm2 (14 AWG) conductor

Push ON/OFF switch to ON () position and heater should start in 5 seconds. If ON/OFF switch light does not come on or heater does not start, see Troubleshooting (pages 6 and 7).

TO STOP HEATER

Push ON/OFF switch to OFF (O)position.

TO RESET HEATER

1.Push ON/OFF switch to OFF (O) position and wait 10 sec- onds (2 minutes if heater has been running).

2.Repeat steps under To Start Heater, above.

 

 

ON/OFF

ON/OFF Switch

Switch with

 

O

Light

O

with Light

 

 

STORING, TRANSPORTING, OR SHIPPING

Note: If shipping, transport companies require fuel tanks to be empty.

1.Drain fuel tank.

Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.

2.Replace drain plug if provided.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent ex- cess debris from clogging filters during future use.

4.Replace fuel cap or drain plug. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

Figure 5 - ON/OFF Switch,

Figure 6 - ON/OFF Switch,

Model GK20

Model GK30

108954

Page 7
Image 7
Desa GK30, GK20 Operation, Storing, Transporting, Or Shipping, To Start Heater, Extension Cord Wire Size Requirements