Chapter 9 Product Installation and
Figure 13. DC Power Supply Module Terminal Block
DC Power Supply Module
Terminal Block Connections
Insulating
Cover
The product is supplied with an insulating cover over the terminal block. To gain access to the terminals, apply gentle pressure to flip up the cover, while using a small flat blade screwdriver to unlatch each side in turn. When the wiring is complete the cover must be flipped down, and securely latched at both sides. All wiring terminals connected to the DC power input terminal block must be insulated, with no accessible bare metal when the cover is closed.
When installing a second Power Supply Module to provide the
Each DC power input terminal block has two positive and two negative terminals as shown in Figure 14. Normally, only one pair (+ and
Figure 14. DC Power Input Connector
The terminal block accepts standard terminal lugs that accept 14 AWG wire gauge, for example, Network™ stock # 81N1501 type
52