Image 64
Figure 22. Dialogic® SS7HDP Board Layout

Chapter 10 Working Inside the Product

Note: If only two SS7HDP Signaling Boards are installed, then the middle position (No.2) should remain empty.

Table 14. Signaling Board Positions and Configurations for Dialogic® SS7G22 Product Variants

 

Quantity of Boards (Variant Suffix)

 

 

Board Position

ADDR

 

 

 

 

 

 

 

 

 

0 boards

1 board

2 boards

 

3 boards

No.

 

Position

Switch

(00W)

(H1W)

(H2W)

 

(H3W)

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

Blank

Blank

SS7HDP

 

SS7HDP

3

 

Top

2

 

 

 

 

 

 

 

 

 

Blank

Blank

Blank

 

SS7HDP

2

 

Middle

1

 

 

 

 

 

 

 

 

 

Blank

SS7HDP

SS7HDP

 

SS7HDP

1

 

Bottom

0

 

 

 

 

 

 

 

 

 

Figure 22. Dialogic® SS7HDP Board Layout

H.100 Edge

Connector

LEDs

ADDR

Base

Board

License

Button

Holder

ENET

Port

 

Daughter

Port L1

Board

Port L2

Port L3

Port L4

End

Bracket

Prepare an SS7HDP Signaling Board for installation as follows:

ISA Edge H.100 Edge Retainer

1.Unscrew and discard the ISA edge retainer from a new SS7HDP Signaling Board (right end in Figure 22). Record the board and software License Button serial numbers on your product records, then fit the Licence Button.

2.Set the ADDR switch on the SS7HDP Signaling Board as in Table 14.

Note: The ADDR switch setting number is used only for internal functionality of the product. The board position number must be used for all configuration and wiring schedule purposes.

10.5.3Installing or Replacing an SS7 Signaling Board

Installation of extra SS7 Signaling Boards in positions No. 2 and No. 3, or replacement of a board in any position, follow basically the same steps, but ensure that in each case the SS7 Signaling Board fitted is correctly configured as identified in Table 13, “Signaling Board Positions and Configurations for SS7G21 Product Variants” on page 63 and Table 14, “Signaling Board Positions and Configurations for Dialogic® SS7G22 Product Variants” on page 64.

Install/Replace an SS7 Signaling Board as follows, referring to Figure 23: 1. Remove the Top Cover. See Section 10.3.

64