112 Dolby® DP570 Multichannel Audio Tool User’s Manual
Regulatory Notices and Fuse Information Fuse Information
E.3.1 Main FuseThemainfuseratingisT1AL(1amp,250V,20mm,time‐lag,lowbreakingcapacity)for
alloperatingvoltages.
Toinspectorreplacethemainfuse:
1. OpenthefusecompartmentdoorintheACpowerinputhousingwithasmall
flat‐bladescrewdriver.SeeFigureE‐1.
2. Checkthatthefuseintheactive(lower)fusecarrieristhecorrectrating.Thefuse
carriermustbeinsertedintothecompartmentwiththeorientationshownin
Figure E‐1.Donotforcethecarrierintothecompartmentorbothcouldbedamaged.
3. Snapthefusecompartmentdoorclosed.
Figure E-1 Fuse Replacement
E.3.2 Internal FuseTheswitchingpowersupplycontainsaseparatefuse.Mostfaultconditionsshouldbe
protectedbythemainfuse.TheinternalfuseratingisF2AL(2amp,250V,20mm,
fast‐acting,lowbreakingcapacity)foralloperatingvoltages.
Warni ng:Thepowertotheunitmustbeoffwhenthefollowingstepsareperformed.
Ensurethatthemainpowercabletotheunitisnotconnectedtoapowersource.
OPENTHE
DOOR
METALCLIP INSTALLED
ON SIDEOFUNUSED
CARRIER
ACTIVE
FUSE
INSTALL
FUSE
TOP
FUSE
CARRIER