SAFETY INFORMATION
4
FCC EXPOSURE LIMITS

This mobile radio transceiver was tested by the manufacturer with

an appropriate antenna in order to verify compliance with Maximum Per-

missible Exposure (MPE) limits set under Section 2.1091 of the FCC

Rules and Regulations. The guidelines used in the evaluation are derived

from Table 1 (B) titled “Limits For General Population/Uncontrolled

Exposure” which is from FCC report OET bulletin #65.

Table 1

FCC Limits for Maximum Permissible Exposure (MPE)

(A) Limits For Occupational/Controlled Exposure

Frequency Range
(MHz)
Electric Field
Strength (E)
(V/m)
Magnetic Field
Strength (H)
(A/m)
Power Density
(S)
(mW/cm22)
Averag in g
Time |E|2, |H|2,
S (minutes)
0.3-3.0 614 1.63 (100)* 6
3.0-30 1842/f 4.89/f (900/f2)* 6
30-300 61.4 0.163 1.0 6
300-1500 -- -- f/300 6
1500-100,000 -- -- 5 6

(B) Limits For General Population/Uncontrolled Exposure

Frequency Range
(MHz)
Electric Field
Strength (E)
(V/m)
Magnetic Field
Strength (H)
(A/m)
Power Density
(S)
(mW/cm22)
Averag in g
Time |E|2, |H|2,
S (minutes)
0.3-1.34 614 1.63 (100)* 30
1.34-30 824/f 2.19/f (180/f2)* 30
30-300 27.5 0.073 0.2 30
300-1500 -- -- f/1500 30
1500-100,000 -- -- 1.0 30
f = Frequency in MHz *Plane-wave equival ent power density