Emerson 00825-0100-4530 Rev EC European certifications, ATEX approvals, March, E11 Flameproof

Models: 00825-0100-4530 Rev EC

1 36
Download 36 pages 54.13 Kb
Page 27
Image 27
European certifications

March 2013

Quick Installation Guide

European certifications

ATEX approvals

Special conditions for safe use (X)

The intrinsically safe circuits do not withstand the 500 V AC test as specified in IEC 60079-11 clause 6.4.12.

Impact and friction hazards need to be considered according to EN 60079-0 clause 8.1.2 when the transmitter and part of antennas exposed to the exterior atmosphere of the tank is made with light metal alloys and of category II 1G EPL Ga.

The Ex ia version of model 5300 FISCO field device may be supplied by an [Ex ib] FISCO power supply when the power supply is certified with three separate safety current limiting devices and voltage limitation which meets the requirements for type Ex ia.

E11 Flameproof:

Nemko 04ATEX1073X

ATEX approvals II 1/2 G T4

II 1D T79 °C2

Ex ia/db ia IIC T4 Ga/Gb (-40 °C < Ta < +70 °C3)

Ex ta IIIC T79 °C2 (-40 °C < Ta < +70 °C3)

Um = 250 V

Approval valid for HART, FOUNDATION fieldbus, and Modbus options.

I1, IA1 Intrinsically safe and FISCO model:

Nemko 04ATEX1073X Special conditions for safe use (X) II 1 G T4 or

E11 Flameproof: II 1/2 G T4 II 1 D T79 °C2

Ex ia IIC T4 (-50 °C < Ta < +70 °C3)

Ex ia/ib IIC T4 Ga/Gb (-50 °C < Ta < +60 °C) Ex ta IIIC T79 °C2 (-50 °C < Ta < +70 °C3)

4-20 mA/HART model: Ui = 30 Vdc, Ii = 130 mA, Pi = 1.0 W, Ci = 7.26 nF, Li = 0 H.

FOUNDATION fieldbus model: Ui = 30 Vdc, Ii = 300 mA, Pi = 1.5 W, Ci = 4.95 nF, Li = 0 H.

FISCO model: Ui = 17.5 Vdc, Ii = 380 mA, Pi = 5.32 W, Ci = 4.95 nF, Li < 1 μH.

Installation Drawing: 9240 030-938

Approval valid for HART, FOUNDATION fieldbus, and FISCO options.

N11 Type n:

I1, IA1 Intrinsically safe and FISCO model: II 3G Ex nAnL IIC T4 Gc (-50 °C < Ta < +70 °C3)

N11 Type n: II 3G Ex nL IIC T4 Gc (-50 °C < Ta < +70 °C3) Nemko 10ATEX1072

4-20 mA/HART model: Un = 42.4 V

FOUNDATION fieldbus model: Un = 32 V

Approval valid for HART and FOUNDATION fieldbus options.

1)Ordering information code for Product Certifications, see the Rosemount 5300 Series Product Data Sheet (Document No. 00813-0100-4530) or the Rosemount 5300 Series Reference Manual

(Document No. 00809-0100-4530).

2)+69 °C with FOUNDATION fieldbus or FISCO option.

3)+60 °C with FOUNDATION fieldbus or FISCO option.