HART communication

The Rosemount 5300 Series transmitter operates with a power supply ranging from 16 - 42.4 Vdc (16 - 30 Vdc in IS applications, 20-42.4 Vdc in Explosion-proof / Flameproof applications and in Non-Sparking / Energy Limited applications).

All configuration tools for HART communication, such as the Field Communicator and Rosemount Radar Master, require a minimum load resistance (RL) of 250 Ω within the loop in order to function properly, see diagrams below.

Non-intrinsically safe power supply

 

 

 

Field

Rosemount 5300 Series

 

 

PC

Communicator

Transmitter

 

 

 

 

 

 

HART

 

 

 

 

Modem

 

 

Power

Load Resistance

 

 

Supply

 

 

250

Ω

 

 

 

 

 

NOTE:

Rosemount 5300 Series Transmitters with Flameproof/Explosion-proof output have a built-in barrier; no external barrier needed.

Intrinsically safe power supply

 

 

 

Field

Rosemount 5300 Series

 

PC

Communicator

Transmitter

 

HART

 

 

 

 

Modem

 

Power

 

 

 

 

Supply

RL=250

Ω

 

 

 

 

 

ApprovedIS

Barrier

For IS Parameters, see the Product certifications chapter.