IECEx certifications

March 2013

Quick Installation Guide

IECEx certifications

IECEx approvals

Special conditions for safe use (X)

The intrinsically safe circuits do not withstand the 500 V AC test as specified in IEC 60079-11 clause 6.4.12.

Impact and friction hazards need to be considered according to EN 60079-0 clause 8.1.2 when the transmitter and part of antennas exposed to the exterior atmosphere of the tank is made with light metal alloys and of category EPL Ga.

The Ex ia version of model 5300 FISCO field device may be supplied by an [Ex ib] FISCO power supply when the power supply is certified with three separate safety current limiting devices and voltage limitation which meets the requirements for type Ex ia.

E71 Flameproof:

IECEx NEM 06.0001X

Ex ia/db ia IIC T4 Ga/Gb (-40 °C < Ta < +70 °C2)

Ex ta IIIC T 79 °C3 (-40 °C < Ta < +70 °C2)

Um = 250 V.

Approval valid for HART, FOUNDATION fieldbus, and Modbus options.

I7, IG1 Intrinsically safe and FISCO model:

IECEx NEM 06.0001X

Ex ia IIC T4 (-50 °C < Ta < +70 °C2).

Ex ia/ib IIC T4 Ga/Gb (-50 °C < Ta < +60 °C). Ex ta IIIC T 79 °C3 (-50 °C < Ta < +70 °C2).

4-20 mA/HART model: Ui = 30 Vdc, Ii = 130 mA, Pi = 1.0 W, Ci = 7.26 nF, Li = 0 H.

FOUNDATION fieldbus model: Ui = 30 Vdc, Ii = 300 mA, Pi = 1.5 W, Ci = 4.95 nF, Li = 0 H.

FISCO model: Ui = 17.5 Vdc, Ii = 380 mA, Pi = 5.32 W, Ci = 4.95 nF, Li < 1 μH.

Installation Drawing: 9240 030-938

Approval valid for HART, FOUNDATION fieldbus, and FISCO options.

N71 Type n:

Ex nAnL IIC T4 (-50 °C < Ta < +70 °C2) Ex n IIC T4 (-50 °C < Ta < +70 °C2) IECEx NEM 10.0005

4-20 mA/HART model: Un = 42.4 V

FOUNDATION fieldbus model: Un = 32 V

Approval valid for HART and FOUNDATION fieldbus options.

1)Ordering information code for Product Certifications, see the Rosemount 5300 Series Product Data Sheet (Document No. 00813-0100-4530) or the Rosemount 5300 Series Reference Manual

(Document No. 00809-0100-4530).

2)+60 °C with FOUNDATION fieldbus or FISCO option.