A |
Mode Select Parameter List: Page 4 Parameters for Winchester drives
| BYTE OFFSET | VALUE | COMMENTS | |
|
|
| ||
|
|
|
|
|
0 | 4 | Page code | ||
|
|
| ||
1 | 12 | Page length | ||
|
|
| ||
2 | (Note 1) | Number of cylinders (MSB) | ||
|
|
| ||
3 | (Note 1) | Number of cylinders | ||
|
|
| ||
4 | (Note 1) | Number of cylinders (LSB) | ||
|
|
| ||
5 | (Note 2) | Number of heads | ||
|
|
| ||
6 | (Note 3) | Starting cylinder - write precomp | ||
|
|
|
| |
|
|
| (MSB) | |
|
|
| ||
7 | (Note 3) | Starting cylinder - write precomp | ||
|
|
| ||
8 | (Note 3) | Starting cylinder - write precomp | ||
|
|
|
| |
|
|
| (LSB) | |
|
|
| ||
9 | (Note 4) | Starting cylinder - reduced write | ||
|
|
|
| |
|
|
| current (MSB) | |
|
|
|
| |
| A | (Note 4) | Starting cylinder - reduced write | |
|
|
|
| |
|
|
| current | |
|
|
|
| |
| B | (Note 4) | Starting cylinder - reduced write | |
|
|
|
| |
|
|
| current (LSB) | |
|
|
|
| |
| C | (Note 5) | Drive step rate (MSB) | |
|
|
|
| |
| D | (Note 5) | Drive step rate (LSB) | |
|
|
|
| |
| E | (Note 6) | Landing zone cylinder (MSB) | |
|
|
|
| |
| F | (Note 6) | Landing zone cylinder | |
|
|
|
|
|
Mode Select Parameter List: Page 4 Parameters for Winchester drives (cont’d)
| BYTE OFFSET | VALUE | COMMENTS | |
|
|
| ||
|
|
|
|
|
10 | (Note 6) | Landing zone cylinder (LSB) | ||
|
|
| ||
11 | (Note 7) | Reserved | ||
|
|
| ||
12 | (Note 7) | Reserved | ||
|
|
| ||
13 | (Note 7) | Reserved | ||
|
|
|
|
|