Emerson MVME147 manual Verify CRC Packet, The controller must be in general or read mode

Models: MVME147

1 170
Download 170 pages 32.5 Kb
Page 131
Image 131
Verify CRC Packet

Verify CRC Packet

7

 

Verify CRC Packet

The verify Cyclic Redundancy Character (CRC) command ($13) instructs the controller to read the specified number of blocks and check the CRC of each block. The verify begins at the current tape position and the tape is left positioned at the end of the last block verified. No data is transferred to the MVME147 during this operation.

Note

The controller must be in general or read mode.

The table below shows the verify CRC packet.

Even Byte \

Odd Byte \

 

FC

 

 

B8

74

 

30

 

 

 

 

 

 

 

 

+$00

 

 

Controller LUN

 

Device LUN

 

 

 

 

 

+$02

 

 

Status Byte 0

Status Byte 1 (Note 1)

 

 

 

 

 

 

 

+$04

 

 

 

Number of Blocks (MSW)

 

 

 

 

 

+$06

 

 

 

Number of Blocks (LSW)

 

 

 

 

 

 

 

+$08

 

0

 

0

0

 

0

 

 

 

 

 

 

 

 

+$0A

 

0

 

0

0

 

0

 

 

 

 

 

 

 

 

+$0C

 

0

 

0

0

 

0

 

 

 

 

 

 

 

 

+$0E

 

0

 

0

0

 

0

 

 

 

 

 

 

 

 

+$10

 

0

 

0

0

 

0

 

 

 

 

 

 

 

 

+$12

 

0

 

0

0

 

0

 

 

 

 

 

 

 

+$14

 

0

 

0

Function Code (40)

 

 

 

 

 

 

 

 

+$16

 

 

Interrupt Level

 

Vector Number

 

 

 

 

 

+$18

 

 

Status Byte 2

Status Byte 3 (Note 1)

 

 

 

 

 

 

 

$00

 

00000xxx

 

Controller logical unit

 

 

 

 

 

 

number

$01

 

00000xxx

 

Device logical unit

 

 

 

 

 

 

number

7-51

Page 131
Image 131
Emerson MVME147 manual Verify CRC Packet, The controller must be in general or read mode