Emerson MVME147 manual Assign Alternate Sector Packet SCSI

Models: MVME147

1 170
Download 170 pages 32.5 Kb
Page 115
Image 115
Manual background

Assign Alternate Sector Packet (SCSI)

7

6

5

4

3

2

1

0

CL

DP

DC

SF

R

R

R

R

CL Complete List

Clear and no defect list is supplied. Use existing grown defect list, no user list is supplied.

Clear and defect list is supplied. Use existing grown defect list, add user list to the grown list.

Set and no defect list is supplied. Do not use existing grown defect list, no user list is supplied.

Set and defect list is supplied. Do not use existing grown defect list, use user list as the complete defect list.

DP Disable Primary List of Defects

Clear. Use manufacturer’s primary list if the controller/drive supports it.

Set. Do not use manufacturer’s primary list.

DC Disable Certification Process

Clear. Use certification if the controller/drive supports it. (Drive is certified at format time.)

Set. Do not use certification.

SF Stop Format

Set. Format even if a controller/drive defect list cannot be accessed.

Clear. Stop formatting when any of the controller/drive defect lists cannot be accessed.

R Reserved

$15

xxxxxxxx

SCSI function ($10 =

 

 

format, $14 = assign

 

 

alternate

$16

000000xx

Interrupt level (7

 

 

through 0) (0 = polled

 

 

mode

7

7-35

Page 115
Image 115