Emerson MVME7100 manual SMT Configuration Switch, S1, 4 SMT Configuration Switch Position

Models: MVME7100

1 106
Download 106 pages 17.7 Kb
Page 37
Image 37
2.4.1SMT Configuration Switch, S1

SMT Configuration Switch, S1

Hardware Preparation and Installation

 

 

The following sections describe the on-board switches and their configurations for the MVME7100.

Board Malfunction

Switches marked as “reserved” might carry production-related functions and can cause the board to malfunction if their setting is changed.

Do not change settings of switches marked as “reserved”. The setting of switches which are not marked as “reserved” has to be checked and changed before board installation.

2.4.1SMT Configuration Switch, S1

An 8-position SMT configuration switch (S1) is located on the MVME7100 to control the flash bank write-protect, select the flash boot image, and control the safe start ENV settings. The default setting on all switch positions is OFF and is indicated by brackets in Table 2-5.

Figure 2-4 SMT Configuration Switch Position

1 Normal ENV Boot Block A

WP Disabled

Normal Operation

Normal Operation

PMC 133 MHz

Master WP

Reserved

1 Figure 2-4 SMT Configuration Switch PositionTable 2-5 Configuration Switch Settings (S1)Manual backgroundManual backgroundManual background ON

2

3

4

5

6

7

8

Table 2-5 Configuration Switch Settings (S1)

 

Switch

Description

Setting

Function

 

 

 

 

 

 

 

 

S1-1

Safe Start1

[OFF]

Use normal ENV

 

 

 

 

ON

Use safe ENV

 

 

 

 

 

 

 

 

S1-2

Boot Block B

[OFF]

Flash memory map normal and boot block A selected

 

 

 

Select

ON

Boot block B selected, mapped to highest address

 

 

 

 

 

 

 

 

 

 

 

 

S1-3

Flash Bank WP

[OFF]

Entire flash not write-protected

 

 

 

 

ON

Flash is write-protected

 

 

 

 

 

 

 

 

S1-4

JTAG Pass Thru

[OFF]

Normal operation

 

 

 

 

ON

Pass-Thru mode

 

 

 

 

 

 

 

 

 

 

 

 

 

MVME7100 Single Board Computer Installation and Use (6806800E08A)

37

Page 37
Image 37
Emerson MVME7100 SMT Configuration Switch, S1, 4 SMT Configuration Switch Position, 5 Configuration Switch Settings S1