Enterasys Networks ELS10-27TX manual Configuring Vlans Using Snmp Overview, Config Table

Models: ELS10-27TX

1 98
Download 98 pages 42.84 Kb
Page 43
Image 43

CHAPTER 3

CONFIGURING VLANS USING SNMP

3.1 OVERVIEW

This chapter describes how to create, delete or modify VLANs on the SmartSTACK Ethernet ELS10-27TX using SNMP. This chapter describes the procedure for using the following VLAN Configuration MIBs:

The Config Table

The Config Egress List

802.1Q Mode

The Filter GVRP table

The Static MAC table

This chapter should be used in conjunction with Chapter 4, VLAN MIB Objects, in this manual.

3.2 THE CONFIG TABLE

The SmartSTACK Ethernet ELS10-27TX is capable of supporting 32 VLANs. The index into the VLAN table is from 0 to 31. The present table entries can be read, but not written, by setting the index to a value of 0 - 31. When configuring an entry, several values are used. These values are the VLAN ID, the ports on the VLAN, an IP address, an IP mask, and a VLAN name.

If the index is between 0 and 31, and one of these variables is read, the presently configured table entry will be returned.

To create, modify, or delete a VLAN entry, a multiple step process is required. The local variables must first be set with the values desired, followed by a command to process the variables. For a list of configuration MIBs, refer to Chapter 3, VLAN MIB Objects.

3-1

Page 43
Image 43
Enterasys Networks ELS10-27TX manual Configuring Vlans Using Snmp Overview, Config Table