A794 Owner’s Guide | Chapter 6: Programming Information |
Real Time Status Transmission (continued)
2 = Transmit RS-232C Busy Status
Bit | Status | Hex | Decimal | Function |
0 | Off | 00 | 0 | Fixed to Off. |
1 | On | 02 | 2 | Fixed to On. |
2 | Off | 00 | 0 | Cover closed. |
| On | 04 | 4 | Cover open. |
3 | Off | 00 | 0 | Paper feed button is not pressed. |
| On | 08 | 8 | Paper feed button is pressed. |
4 | On | 10 | 16 | Fixed to On. |
5 | Off | 00 | 0 | Printing not stopped due to paper condition. |
| On | 20 | 32 | Printing stopped due to paper condition. |
6 | Off | 00 | 0 | No error condition. |
| On | 40 | 64 | Error condition exists in the printer. |
7 | Off | 00 | 0 | Fixed to Off. |
3 = Transmit Error Status
Bit | Status | Hex | Decimal | Function |
0 | Off | 00 | 0 | Fixed to Off. |
1 | On | 02 | 2 | Fixed to On. |
2 | Off | 00 | 0 | Fixed to Off. |
|
|
|
|
|
3 | Off | 00 | 0 | No knife error. |
| On | 08 | 8 | Knife error occurred. |
4 | On | 10 | 16 | Fixed to On. |
5 | Off | 00 | 0 | No unrecoverable error. |
| On | 20 | 32 | Unrecoverable error occurred. |
6 | Off | 00 | 0 |
On 40 64
Thermal printhead temp. and power supply voltage are in range.
Thermal print head temp. or power supply voltage are out of range.
7 | Off | 00 | 0 | Fixed to Off |
March 1999 | 105 |