A794 Owner’s Guide

Chapter 6: Programming Information

Real Time Printer Status Transmission

Transmits one byte status of the printer in real time.

ASCII

 

GS ENQ

 

Hexadecimal

1D 05

 

 

Decimal

29 5

 

 

Value of Byte

 

 

 

Bit

Status

Hex

Decimal

Function

0

Off

00

0

Paper adequate.

 

On

01

1

Paper low (if paper low sensor

 

 

 

 

enabled).

1

Off

00

0

Paper adequate.

 

On

02

2

Paper low (if paper low sensor

 

 

 

 

enabled).

2

Off

00

0

Cover closed.

 

On

04

4

Cover open.

3

Off

00

0

Not busy at the RS-232C interface.

 

On

08

8

Printer is busy at the RS-232C interface.

4

Off

00

0

One or both cash drawers open.

 

On

10

16

Both cash drawers closed.

5

Off

00

0

Fixed to Off.

6

Off

00

0

No error condition.

 

On

40

64

Error condition exists in the printer.

7

On

80

128

Fixed to On.

March 1999

107

Page 113
Image 113
Epson A794-D100 manual Real Time Printer Status Transmission, Hexadecimal Decimal Value of Byte