Select Memory Type (SRAM/Flash) Where to Save Logos or User-Defined Fonts

Specifies whether to load the logos or user-defined characters to flash memory or to RAM (volatile memory). The selection remains in effect until it is changed via this command or until the power cycles.

ASCII

GS " n

Hexadecimal

1D 22 n

Decimal

29 34 n

Value of n

48-51

n = 48 (ASCII n = 0)

Loads active logo to RAM only. This is used to print a special logo but not have it take up flash memory. A logo defined following this command is not preserved over a power cycle.

n = 49 (ASCII n = 1)

Loads active logo to flash memory. This is the default condition for logo flash storage. A logo defined following this command is stored in flash memory.

n = 50 (ASCII n = 2)

Loads user-defined characters to RAM only. This is the default condition for user- defined character storage. Any user-defined characters defined following this command are not preserved over a power cycle.

n = 51 (ASCII n = 3)

Loads user-defined characters to flash memory. An application must use this command to store user-defined characters in flash memory. Any user-defined characters defined following this command are stored in flash memory. A user-defined character cannot be redefined in flash memory. The flash memory page must be erased by an application before redefining user-defined characters. For more information, see the Erase User Flash Sector (1D 40 n) Command earlier in this section.