Chapter 6: Programming Information | A794 Owner’s Guide |
Select Sensors to Stop Printing
Selects the paper sensor used to detect when the paper is out. The printer finishes printing the current line and feeds the paper before stopping.
ASCII |
| ESC c 4 n |
|
|
Hexadecimal | 1B 63 34 n |
|
| |
Decimal |
| 27 99 52 n |
|
|
Value of n | Sensor status |
|
| |
|
|
| Sensor Status | |
|
|
|
|
|
Bit | Sensor |
| 0 | 1 |
|
|
|
| |
0 | Receipt Paper | Disabled | Enabled | |
1 | Receipt Paper | Disabled | Enabled | |
Undefined |
|
| ||
6 | Undefined |
|
| |
Bits 5 and 7 are not used. |
|
| ||
Default |
| 0 |
|
|
Enable or Disable Panel Button
Enables or disables the paper feed button by toggling the paper feed button on and off. Only the lowest bit is used to toggle the paper feed button. If the last bit is 0, the paper feed button is enabled. If the last bit is 1, the paper feed button is disabled.
ASCII | ESC c 5 n | |
Hexadecimal | 1B 63 35 n | |
Decimal | 27 99 53 n | |
Value of n | 0 | = Enable |
| 1 | = Disable |
Default | 0 | (Enable) |
Exceptions
Functions that require the panel button cannot be used when it has been disabled with this command.
52 | March 1999 |