122 EPSON S5U1C62000A MANUAL
(S1C60/62 FAMILY ASSEMBLER PACKAGE)
CHAPTER 9: DEBUGGER
9.3.3 Start-up Messages
When Debugger db62 starts up, it outputs the following message in the [Command] window. (Refer to
the next section for details about windows.)
Debugger for E0C62 Ver x.x Copyright (C) SEIKO EPSON CORP. 199x
Connecting COMx with xxxxx baud rate...done
Parameter file: XXXXX.par
Chip name: E0C62XX
Map....................................done
Initialize.............................done
>
9.3.4 Hardware Check at Start-up
If the debugger is invoked, it first performs the tests and initializing operations as follows:
(1) The debugger first checks to see that the ICE is connected to the system and that communication is
possible without any problems. The following message is displayed in the [Command] window.
During test
Connecting COMx with xxxxx baud rate...
When terminated normally
Connecting COMx with xxxxx baud rate...done
When an error is encountered
Connecting COMx with xxxxx baud rate...Error
The Error indicates that communication between the personal computer and ICE is not functioning
properly. In this case, verify the following:
• A standard RS-232C cable is used
• The COM port is correct
• The baud rates on both sides are matched
• The ICE's power is turned on
• The ICE remains reset
(2) When the connection test terminates normally, the debugger checks the contents of the parameter file
and initializes the ICE.
When terminated normally
Parameter file: XXXXX.par
Chip name: E0C62XX
Map....................................done
Initialize.............................done
>
When an error is encountered
Parameter file: XXXXX.par
Chip name: E0C62XX
Map....................................Error
Initialize.............................Error
>
If an error occurs in the above initialization process, temporarily quit the debugger. Check the cause