S5U1C62000A MANUAL EPSON 181
(S1C60/62 FAMILY ASSEMBLER PACKAGE)
CHAPTER 9: DEBUGGER
br (register break)
Function
This command sets or clears register break. This command allows you to specify data or a mask that
constitutes a break condition for each register (A, B, F, X, and Y). The program will break when all
setting conditions are met.
Format
(1) >br <register> <value> [<register> <value> [...<register> <value>]](direct input mode)
(2) >br(guidance mode)

Register break set status

1. set 2. clear …? <1 | 2>(Command is completed when "2" is selected.)
A
Old value
: <value>
B
Old value
: <value>
FI
Old value
: <value>
FD
Old value
: <value>
FZ
Old value
: <value>
FC
Old value
: <value>
X
Old value
: <value>
Y
Old value
: <value>
><register>: Register name; A, B, F, X or Y
<value>: Data pattern for the register; hexadecimal or binary with 'B' suffix (* can be used for the bits to
be masked)
Examples
Format (1)
>br F ***1B... Sets a register break condition so that the program breaks when the C flag is set.
Format (2)
>br
Register break: None
1. set 2. clear ...? 1... "1. set" is selected.
A - : a... Data 0xa is set for A register condition.
B - : *... "*" masks the register condition.
FI - : 1
FD - : *
FZ - : 0
FC - : *
X - : 20
Y - : ^... "^" returns guidance to previous setting.
X 020 : 60
Y - : *
>br
A:A B:* X:060 Y:* IDZC:1*0*B
1. set 2. clear ...? 2... "2. clear" is selected.
>br
Register break: None
1. set 2. clear ...? ... Terminated by [Enter] key.