Ericsson LBI-39169 Status Colors/Levels, Category Status Status Meaning Condition, Icon Color

Models: LBI-39169

1 90
Download 90 pages 40.41 Kb
Page 27
Image 27

MONITORING EDACS FAULT CONDITIONS

LBI-39169

 

 

Table 1 - Status Colors/Levels

 

 

 

 

Category

Status

Status Meaning

 

 

Condition

 

 

 

 

 

 

Administrative

Unmanaged

Users can set this value, which indicates that

 

 

 

the object should not be monitored and that the

 

 

 

status should be ignored. When the user sets

 

 

 

the object back to “managed.” the EDACS-

 

 

 

>Fault->Update operation must be performed.

 

 

 

 

 

Administrative

Testing

An application sets the status to “testing” when

 

 

 

an object is undergoing temporary diagnostic

 

 

 

or maintenance procedures. This category is

 

 

 

not used by the EDACS Network Manager

 

 

 

application.

 

 

 

 

 

Administrative

Restricted

An application sets the status to “restricted”

 

 

 

when a valid associated CEC/IMC/RCEC/SG

 

 

 

node license does not exist for this element.

 

 

 

 

 

Administrative

Shutdown

An application sets the status to “shutdown”

 

 

 

when an object is inactive (although there may

 

 

 

not be anything necessarily wrong with the

 

 

 

object). This category is not used by the

 

 

 

EDACS Network Manager application.

 

 

 

 

 

Operational

Unknown

An application sets the status to “unknown”

 

 

 

when the status of an object cannot be

 

 

 

determined. EDACS icon may be blue if there

 

 

 

is another icon with the same Network Number

 

 

 

and Node Number or if polling does not detect

 

 

 

a physical device corresponding to this icon.

 

 

 

 

 

Operational

Normal

An application sets the status to “normal” when

 

 

 

the object is in a normal operational state.

 

 

 

 

 

Operational

Warning

An application sets the status to “warning”

 

 

 

when an object may face a potential problem.

 

 

 

 

 

Operational

Minor/

An application sets the status to

 

 

Marginal

“minor/marginal” when an object has a minor

 

 

problem; this status should not, however,

 

 

 

 

 

 

impede the normal operation of the network.

 

 

 

 

 

Operational

Major

An application sets the status to “major” when

 

 

 

an object has serious problems; these

 

 

 

problems are likely to impede normal use of

 

 

 

the network.

 

 

 

 

 

Operational

Critical

An application sets the status to “critical” when

 

 

 

a device is not functioning or is not accessible

 

 

 

by the EDACS Network Manager.

 

 

 

 

 

 

 

 

 

Icon Color

Off-white

Salmon

Tan

Dark Brown

Blue

Green

Cyan

Yellow

Orange

Red

27

Page 27
Image 27