LBI-39169

PROCEDURES

2.Select the enterprise of the agent reporting the traps, and the traps defined for the agent will be displayed in the middle window. The severity level will be displayed in the middle window along with the trap name. The first characters of an EDACS trap name conventionally are an acronym of the device against which the trap is placed.

3.Click on the Modify button and a window will popup.

4.Modify the text as required. NOTE: Modifications will be overwritten when the application is upgraded.

5.Select the OK button to exit this popup and click on the Apply button on the Event Configuration window for the changes to take effect.

14.15 RESTORING DEFAULT EVENT DESCRIPTIONS

To restore the default event descriptions execute the following command:

>/usr/OV/bin/xnmevents -load /usr/EDACS/conf/C/ed_trapd.conf

14.16MAPPING SEVERITY LEVEL TO ICON COLOR

1.Select Help->Display Legend from the OpenView main menu bar, this will provide a graphical display of the icons and their associated colors.

14.17 CREATING A FULL SYSTEM IMAGE BACKUP

To create a full system image backup, perform the following steps:

1.As root user: Use console login.

>/etc/shutdown now <ENTER>

System will shutdown and come back up in single-user mode. If asked what terminal type, press <Enter>

2.Insert the tape into the tape drive (assume device name = /dev/rmt/·0m).

>cd / <ENTER>

>tar -cvf /dev/rmt/0·m .<ENTER>

NOTEN E

One 90mm tape should handle the entire backup and the backup process will take approximately one hour to complete.

When the backup is complete, carefully label all System Image backup tapes as “Sys ddmmmyyyy Vol # (number of this tape) of # (total number of tapes it took to complete the backup)”.

For example: Sys12DEC1994 Vol 1 of 4.

3.Enter the following command to reboot the workstation.

>/etc/shutdown -r now <ENTER>