Extron electronic 3200 Series, 6400 Series manual Command /RESPONSE Table

Models: 3200 Series 6400 Series

1 72
Download 72 pages 38.53 Kb
Page 36
Image 36

Chapter 4 • Programmer’s Guide

COMMAND/RESPONSE TABLE

Symbol Definitions:

= Escape = CR

 

= CR/LF • = space

 

 

= 1 thru maximum number of inputs

= Ø thru maximum number of inputs (Input Ø = muted output)

= 1 thru maximum number of outputs

= BME number (Ø thru 5)

= Ø dB thru 9 dB (audio gain)

= 1 dB thru 15 dB (audio attenuation)

= Numerical Value –15 thru +9

= 1 thru maximum number of rooms [1Ø max.]

= Ø or 1 (Ø meaning off and 1 meaning on)

= Global preset # (Ø = current ties for system in view) [32 max.]

= Room preset # (Ø = current ties for room in view mode) [1Ø max.]

= Group Mode (follow). A = All (Follow), B = Aud / Vid / RGB breakaway, C = total breakaway

= Delay in ½ second increments [1 Ø max. = 5.Ø seconds] = One digit status of Main and Redundant Power Supplies

Ø = Off or Dead Power supply

1 = No Redundant, using Main Power

2 = Using Redundant Power supply

3 = Has Redundant, using Main Power

= 1 through maximum number of virtual planes

= ØØ through 99 (two digits)

= (Y)es or (N)o, Y = Mute and N = UnMute for RGB or Audio

= Controller software version to the second decimal place

= Ø = No mute, 1 = Video mute, 2 = Audio mute, 3 = Vid. & Aud. mute, – = Not used

= Two digit Virtual output number [16 per room max]

= Two digit Virtual input number

= Four character physical i/o port (BME# + i or o + port#) example 3iØ7

 

,

 

,

 

(Virtual Input Name),

 

(Virtual Output Name) = Maximum

 

 

of 12 alphanumeric characters (upper and lower case) “ ” + - : = / and space.

ASCII to

 

 

 

 

 

 

 

 

HEX

 

Conversion Table

 

 

 

 

CR

 

 

LF

 

·

 

 

 

 

 

1B

ØD

ØA

 

 

 

 

 

!

 

21

 

22

#

23

$

24

 

%

 

25

&

26

27

(

28

 

)

 

29

*

2A

+

2B

,

2C

 

-

 

2D

.

2E

/

2F

Ø

 

1

 

31

2

32

3

33

4

34

 

5

 

35

6

36

7

37

8

38

 

9

 

39

:

3A

;

3B

<

3C

 

=

 

3D

>

3E

?

3F

@

 

 

A

41

 

B

42

C

43

D

44

 

 

E

45

 

F

46

G

47

H

48

 

 

I

49

 

J

4A

K

4B

L

4C

 

 

M

4D

 

N

4E

O

4F

P

 

 

Q

51

 

R

52

S

53

T

54

 

 

U

55

 

V

56

W

57

X

58

 

 

Y

59

 

Z

5A

[

5B

\

5C

 

]

 

5D

^

5E

_

5F

`

 

 

a

61

 

b

62

c

63

d

64

 

 

e

65

 

f

66

g

67

h

68

 

 

i

69

 

j

6A

k

6B

l

6C

 

 

m

6D

 

n

6E

o

6F

p

 

 

q

71

 

r

72

s

73

t

74

 

 

u

75

 

v

76

w

77

x

78

 

 

y

79

 

z

7A

{

7B

7C

 

}

 

7D

~

7E

DEL

7F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIMPLE INSTRUCTION SET COMMANDS (PAGE 1 OF 3)

OUTPUT SWITCHING COMMANDS

 

ASCII (HOST-SWITCHER)

RESPONSE (SWITCHER-HOST)

All

*

!

Out

•In

•All

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

3*21!

 

Out21•InØ3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example explanation: Connect Virtual Output 21 to Virtual Input 3 in all Planes (i.e. Audio Follows Video).

RGB

*

&

Out

•In

•Vid

 

 

 

 

 

 

 

 

 

 

Video

*

%

Out

•In

•Vid

 

 

 

 

 

 

 

 

 

 

Audio

*

$

Out

•In

•Aud

 

 

 

 

 

 

Specific BME

*

* !

Out

•In

•Bme

 

 

 

 

Example

 

11*2*2!

 

OutØ2•In11•BME Ø2

 

 

 

 

 

 

 

 

 

 

Example explanation: Connect physical Output 2 in BME 2 to physical Input 11 in BME 2.

 

 

 

 

 

 

 

 

PRESET COMMANDS

 

ASCII (HOST-SWITCHER)

RESPONSE (SWITCHER-HOST)

Save Current

,

 

Spr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recall

.

 

Rpr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Save for a room

*

,

Rmm

 

•Spr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

3*9

 

RmmØ3•SprØ9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example explanation: Save Current Ties as Preset #9 for Room #3.

Recall for a room

* .

Rmm •Rpr

 

 

 

 

 

 

 

 

 

RGB MUTE COMMANDS

ASCII (HOST-SWITCHER)

RESPONSE (SWITCHER-HOST)

RGB Mute

B

Vmt

 

 

 

 

RGB Un-mute

b

Vmt

 

 

 

 

Note: Where is not included, global RGB mute is activated.

4-3

Extron • Matrix 3200/6400 Series • User’s Manual

Page 36
Image 36
Extron electronic 3200 Series, 6400 Series manual Command /RESPONSE Table