Chapter 5 • Upgrades and Troubleshooting

Upgrade andTroubleshooting Procedures

The following procedures may be done in the field.

Add Front Panel Controller (FPC 1000) - see below.

Installing a Software Upgrade - see Page 5-3.

Swapping RS-232 / RS-422 Ports - see Page 5-4.

Troubleshooting a system problem - see Page 5-5.

Adding Video cards to a Matrix 3200/6400 Video Switcher- see Page 5-7.

Adding BMEs to a Matrix 6400/3200 System - see Page 5-9.

Adding a Front Panel Controller to an existing system

Adding a Front Panel Controller to an existing system involves replacing the blank Access Panel on any BME (except Sync) with the FPC 1000 panel. A system can only have one Front Panel Controller and it must be installed on BME #0. The details for installing the FPC 1000 are included in the User’s Manual provided with the unit.

RGB

 

 

 

 

 

MUTE

 

 

 

 

 

AUDIO

 

 

 

 

 

MUTE

 

 

 

 

 

 

 

 

 

 

FPC-1000

POWER SUPPLIES

COMMUNICATIONS

SYSTEM

+V

-V

RS232

BME

REMOTE

STATUS

 

 

PRIMARY

TX

 

 

 

 

REDUNDANT

RX

 

 

MATRIX 6400

 

 

DIAGNOSTICS

 

 

VIDEO

 

 

 

BME

 

 

 

INPUTS

 

 

 

 

 

 

OUTPUTS

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

ADDRESS

 

 

 

 

 

 

 

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

 

 

 

 

 

 

 

 

 

 

B

 

 

IN

1

9

17

25

33

41

49

57

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

COMM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

SYNC

2

10

18

26

34

42

50

58

 

 

 

 

 

 

 

MKP

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

OUT

3

11

19

27

35

43

51

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232/RS422

ANAHEIM, CA

4

12

20

28

36

44

52

60

 

 

 

 

 

 

 

 

MADE IN USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

BME COMM.

 

 

5

13

21

29

37

45

53

61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

6

14

22

30

38

46

54

62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC POWER INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE: 250V 5.0A TT

SERVICING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

15

23

31

39

47

55

63

 

 

 

 

 

 

 

 

 

5.0A MAX 50/60Hz

POWER CORD BEFORE

8

16

24

32

40

48

56

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-240V

DISCONNECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

Figure 5-1.A Matrix 6400 Video BME Front and Rear Panels

5-1

Extron • Matrix 3200/6400 Series • User’s Manual

Page 44
Image 44
Extron electronic 3200 Series Upgrade andTroubleshooting Procedures, Adding a Front Panel Controller to an existing system