PRELIMINARY

Installation, cont’d

You must also configure the LAN port before using it. You can do this by using SIS commands (see “Command/response table for SIS commands” in chapter 4, “Software Configuration and Control”) or by using the Comm./IP Configuration menu on the front panel (see “Comm./IP Configuration menu” in chapter 3, “Operation”).

LAN port defaults:

MGP’s IP address: 192.168.254.254

Gateway IP address: 0.0.0.0

Subnet mask: 255.255.0.0

DHCP: off

E

Reset button — Pressing this recessed button causes various IP functions and

 

Ethernet connection settings to be reset to the factory defaults.

F

Reset LED This green LED, located to the upper-right of the reset button,

 

blinks a varying number of times to indicate which reset mode has been

 

entered. See “Resetting the unit” in chapter 3, “Operation,” for details.

G

BNC output connectors Plug an output device into these five BNC

 

connectors, as shown below.

 

RGBHV

 

 

RGBS

 

 

 

R

G

B

R

G

B

 

/R-Y

/Y

/B-Y

/R-Y

/Y

/B-Y

 

H

V

 

H

V

 

 

/HV

 

 

/HV

 

 

 

R

G

B

R

G

B

 

/R-Y

/Y

/B-Y

/R-Y

/Y

/B-Y

 

H

V

 

H

V

 

 

/HV

 

 

/HV

 

 

 

RGsB

 

 

HD YUV Component Video

 

Connecting to output BNC connectors

 

 

H

 

 

 

 

 

DVI-D OUTPUT

DVI output Plug a DVI output device into this

 

DVI-I connector.

 

 

 

 

NAnalog RGB is not available on the DVI connector.

NWhen two output devices are attached (one to each output connector), they both display the same image.

I

DVI background input — Connect a DVI input source to this DVI-I connector

 

in order to display the DVI video source live as a background on your output

 

screen. The four MGP windows are displayed in front of this DVI image.

 

When a DVI background is used, the MGP output is locked to the input rate

 

of the DVI background. This input is not scaled.

NThis input connector can be used only to receive the background image. The input is not scaled or processed. To process DVI input signals, you must use the MGP 464 DI model.

2-8 MGP 464 • Installation