Command/response table for IP SIS commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

(host to processor)

(host to processor)

(Processor to host)

 

 

Bi-directional serial data port (continued)

Configure mode24

E X! * X2( CY }

W X! %2A X2( CY

Cpn X! • Cty X2( ]

View mode

E X! CP }

W X! CY

X2( ]

Configure flow control24

E X! * X3) , X3! CF }

 

 

 

 

W X! %02A X3) %02C X3! CF

Select serial mode X2( for port X!.

X! = 01 through 99. For X2(:

0 = RS-232

1 = RS-422

NOnly the rear panel RS-232/422 port can be configured. Therefore, X! = 1.

MGP 464 • Software Configuration and Control 4-25

 

 

 

Cpn X! • Cfl X3) , X3! ]

 

 

 

Set flow control type X3) with X3! ms

 

 

 

between bytes. For X3):

 

 

 

H = Hardware.

 

 

 

S = Software.

 

 

 

N = None (default).

 

 

 

X3! = 0000 through 0001; default = 0 ms.

View flow control

E X! CF }

W X! CF

X3) , X3! ]

Configure receive timeout24

E X! * X1& *

X2) * X2# * X2! CE }

Set the time that the MGP will wait for a

response before terminating the command.

 

 

 

WX! %2A X1& %2A X2) %2A X2# %2A X2! CE

Cpn X! • Cce X1& , X2) , X2# , X2! CE ]

NX1& = Time in tens of milliseconds that the MGP will wait until receipt of the first response character before terminating the command. (Default = 10 = 10 ms; max. = 32767.)

X2) = Time in tens of milliseconds that the MGP will wait between characters being received via a serial port before terminating the current command or receive operation. (Default = 20 = 20 ms; max. = 32767.)

X2! = #L or #D. The letter parameter is case sensitive (requires capital D or capital L). For X2!: L = Length of the message to be received,

D = Delimiter value. A delimiter of ASCII 0A = 10D.

#= Byte count (for L) or a single ASCII character expressed in decimal form (for D).

Byte count # can be 0 through 32767; default = 0. The ASCII decimal # can be 0 through 00255; default = the byte count. A 3-byte length = 3L. The response includes leading zeros.

X2# = Priority Status for port X! receiving timeouts. For X2#:

0 = Use Send data string command parameters (default); 1 = Use Configure receive timeout command parameters. The response includes leading zeros.

View receive timeout

E X! CE }

W X! CE

X1& , X2) , X2# , X2! ]

PRELIMINARY