To Add a User

Technical

SECURITY CODES & AUTHORITY LEVELS

Manuals Online!

To Add a User

NOTE: Adding/deleting security codes can only be done from an alpha keypad.

IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones).

 

CODE

1. Enter Master or Manager code and press the

8

key.

2.Enter the new user's 2-digit User Number (02–69).

3.Enter 4-digit security code for that user. The following prompts will appear.

- http://www.tech-man.com

Refer to the #84 Command section for setting usage counter for limited use users.

ADDNEWUSER? 0 = NO ,1 = YES

USERNUMBER =3

ENTERAUTH.LEVEL

RF BUTTON ?

0 = NO,1 = YES

ENTERBUTTONZN #

(01-64)

MULTI-ACCESS? 0 = NO,1 = YES

Enter 1 to add a new user code. Entering 0 will change the existing user's code to the code entered in step 3. SeeChanging A User's Code section.

Enter the authority level, 1–6, for this user within this partition.

1=master

3=operator A

5=operator C

7=Limited Use

2=manager

4=operator B

6=duress code

 

This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user.

Press 1 if a button transmitter will be assigned to this user. Otherwise press 0 .

If assigning a button transmitter, this prompt will appear. Enter the button's zone number (see your installer for zone number).

If you as a user have access to other partitions, the keypad will prompt for ability of this new user to access (GOTO) those partitions. Press 0 (NO) or 1 (YES). If no, the system activates this user code and exits “Add a User” mode. If yes, the keypad prompts for the Global Arm option for this user.