First Alert FA1220CV technical manual Bypassing Protection Zones, Technical, Using the BYPASS Key

Models: FA1220CV

1 60
Download 60 pages 53.78 Kb
Page 15
Image 15
BYPASSING PROTECTION ZONES

Technical

BYPASSING PROTECTION ZONES

Manuals Online! - http://www.tech-man

Using the 6

BYPASS Key

This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful.

Note: The system will not allow fire or emergency zones (keypad panics A, B, C) to be bypassed.

To bypass zones, the system must be disarmed first.

(Your system may include special high security zones. If so, these zones can be bypassed while the system is armed or disarmed. Ask your installer if your system has these zones.)

 

BYPASS

 

1. Enter your security code and press

6

.

2.Enter zone number(s) for the zones to be bypassed (e.g., 01, 02, 03, etc.).

Important! All single-digit numbers must be preceded by a zero (for example, enter 01 for zone 1).

.com

3.BYPASS 07 FRONT UPSTAIRSBEDROOM

Typical bypass message

4.DISARMEDBYPASS READY TOARM

When finished, the keypad will display the word BYPASS along with each bypassed zone number. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses.

Arm the system as usual when the keypad displays "ready" to arm message.

– 15 –

Page 15
Image 15
First Alert FA1220CV Bypassing Protection Zones, Technical, Using the BYPASS Key, Enter your security code and press