First Alert FA1220CV Summary Of Audible Notification, Alpha Display Keypads, Sound, Cause

Models: FA1220CV

1 60
Download 60 pages 53.78 Kb
Page 48
Image 48

Technical Manuals Online! - http://www.tech-man.com

SUMMARY OF AUDIBLE NOTIFICATION

(ALPHA DISPLAY KEYPADS)

SOUND

CAUSE

DISPLAY

LOUD, INTERRUPTED*

FIRE ALARM

FIRE is displayed; descriptor of zone in alarm is displayed.

Keypad & External

 

 

LOUD, CONTINUOUS*

BURGLARY/AUDIBLE

ALARM is displayed; descriptor of zone in alarm is also displayed.

Keypad & External

EMERGENCY ALARM

 

ONE SHORT BEEP

a. SYSTEM DISARM

a. DISARMED/READY TO ARM is displayed.

(not repeated)

b. SYSTEM ARMING ATTEMPT

b. The number and descriptor of the open protection zone is displayed.

Keypad only

WITH AN OPEN ZONE.

 

 

c. BYPASS VERIFY

c. Numbers and descriptors of the bypassed protection zones are displayed

 

 

(One beep is heard for each zone displayed). Subsequently, the following is

 

 

displayed: DISARMED BYPASS Ready to Arm

ONE SHORT BEEP

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

(once every 15 seconds)

 

 

Keypad only

 

 

ONE BEEP every 60 sec.

LOW BATTERY AT A TRANSMITTER

LO BAT displayed with description of transmitter.

Keypad only

 

 

TWO SHORT BEEPS

ARM AWAY OR MAXIMUM

ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is

Keypad only

 

lit.

THREE SHORT BEEPS

a. ARM STAY OR INSTANT

a. ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED

Keypad only

 

is displayed. Red ARMED indicator is lit.

 

b. ZONE OPENED WHILE SYSTEM

b. CHIME displayed, descriptor of open protection zone will be displayed if the

 

IS IN CHIME MODE.

[] key is pressed.

 

c. ENTRY WARNING**

c. DISARM SYSTEM OR ALARM WILL OCCUR is displayed.

RAPID BEEPING

a. TROUBLE

a. CHECK displayed. Descriptor of troubled protection zone is displayed.

Keypad only

b. AC POWER LOSS ALERT***

b. AC LOSS displayed (may alternate with other displays that may be present).

 

c. MEMORY OF ALARM

c. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.

SLOW BEEPING

a. ENTRY DELAY WARNING**

a. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the

Keypad only

 

delay time without disarming causes alarm.

 

b. EXIT DELAY WARNING

b. ARMED AWAY or ARMED MAXIMUM is displayed along with You May

 

(if programmed)

Exit Now

*If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).

– 48 –

Page 48
Image 48
First Alert FA1220CV technical manual Summary Of Audible Notification, Alpha Display Keypads, Sound, Cause