ABOUT THE KEYPADS

Fixed-Word Keypad Displays

Manuals Online!

AWAY: All burglary zones, interior & perimeter, are armed.

STAY: Perimeter burglary zones, such as windows & doors, are armed. Interior zones are bypassed.

INSTANT: Perimeter burglary zones are armed and entry delay is turned off. Interior zones are bypassed.

 

 

 

 

 

0000

AWAY

NO AC

 

AWAY

 

 

NO AC

 

BYPASS

 

 

BYPASS

NOTNOT READYREADY

 

 

 

STAY

CHIME BAT

ALARMALARM STAY

CHIME BAT

FIREFIRE CHECKCHECKINSTANTINSTANT

- http://www.tech-man.com

MAXIMUM:

All burglary zones, interior & perimeter, are armed, and entry delay is turned off.

BYPASS:

One or more burglary protection zones have been bypassed.

NOT READY:

Appears when burglary portion of the system is not ready for arming (due to open protection zones).

READY:

The burglary system is ready to be armed.

NO AC:

Appears when AC power has been cut off. System is operating on backup battery power.

AC:

Appears when AC power is present.

CHIME:

Appears when the CHIME feature is activated.

BAT:

Low battery condition in a wireless sensor (if ID number displayed) or low system battery (if no ID

 

number displayed).

ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire

 

alarm or audible emergency alarm). Accompanied by the protection zone ID in alarm.

CHECK:

Appears when a malfunction is discovered in the system at any time or if a fault is detected in a FIRE

 

zone at any time or in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a

 

display of zone number in trouble. This also appears if the cover of certain wireless transmitters are

 

removed.

FIRE:

Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.