1744/1743 Users Manual

General Specifications

RMS Logging Slow Voltage Variations

Logging values: Mean value

RMS values averaged over interval length

Min, Max values

Averaging with selectable averaging time from

 

0.5 periods to 5 s

Max value

Max 10 ms RMS value per interval

Min value:

Min 10 ms RMS value per interval

Current Logging Values

Mean value

RMS values averaged over interval length

Max value

Highest RMS value per interval

Events Dips, Swells, Interruptions

Limit value

Variable

 

Lower limit: 0 to 95% VN

 

Upper limit: 105 to 120% VN

 

Set in PQ Log

Range

0 to VI + 20%

Logging value

½ period RMS value

Operating uncertainty

< 2% of VI

Response time

½ line power period

Flicker

Logging value

Flicker severity (Pst / Plt) according to

 

IEC 61000-4-15

Intrinsic uncertainty Pst

< 5% of m. v

Measuring range Pst

0.4 to 4

52