Power Quality Logger

Technical Specifications

Logging Function A – “All” parameters

Logging Values

All parameters for voltage quality per EN 50160:

Voltage L1 or A, L2 or B, L3 or C: phase-phase or phase-neutral:

Voltage (mean, max, min values)

Voltage harmonics 1st to 50th order

THDV (harmonic contents of voltage)

Interharmonics 5 to 2500 Hz (in steps of 0.5 Hz)

Flicker Pst,Plt

Unbalance

Signaling voltages

Frequency

Voltage events (dips, swells, interruptions) Current L1 or A, L2 or B, L3 or C, and N:

Current (mean, max values)

Harmonics of phase and neutral currents up to 50th order

Crest factor and peak values of the currents

Power:

Active power P (mean, min, and max values)

Absolute values active power P (mean, min, and max values)

Distorting power D (mean, min, and max values)

Apparent power S (mean, min, and max values)

Power Factor PF, tangent

Energy per averaging interval

55